During 2020, a couple of higher transport volume ActiveControl customers reported performance issues whilst clicking on the WebUI Metrics such as “Awaiting my Approval” or “Awaiting my testing”.

To address this performance constraint, caching has been introduced to the WebUI metrics. When this caching is activated, when a user opens one of the metrics during a session, then if they come out of the screen and then go back into the same metric, the same data will be loaded.

Configuration Steps

The caching of WebUI metrics is done via two new parameters in /BTI/TE_TVARV table in the ActiveControl Domain Controller.

TE_WEBGUI_METRIC_CACHE_TIMEOUT – this is used to set the cache timeout in seconds (default 300)
TE_WEBGUI_TASKLIST_NO_STATS – this is set to X to avoid calculation of task statistics

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.